 ARTICLE VOL 21/4 - 1991  - pp.575-578  - doi:10.1007/BF02970299
TITRE
Mantenimientos de los fibroscopios digestivos entre dos examenes: resultados de una encuesta nacional

TITLE
Hygiene procedure for digestive tract fibroscopes between two examinations: results of a national postal survey

RÉSUMÉ

Informamos los resultados de una encuesta postal nacional efectuada de Enero a Marzo de 1990 entre cerca de 1.000 gastroenteró1ogos endoscopistas que ejercen en el sector público y privado, concerniendo exclusivamente a las modalidades de descontaminación de los fibroscopios digestivos entre dos examenes (lavado, desinfección, enjuague) y las dificultades prácticas encontradas por las personas durante esta descontaminación. Solamente 19% de los endoscopistas interrogados respondieron la encuesta. Se deduce de este estudio que ciertos aspectos de la descontaminacion de los fibroscopios entre un examen y otro, con el fin de reducir los riesgos de alergia y de obstructión de los canales operatorios de los endoscopios, merecen una más amplia difusion : la utilizatión de un producto de lavado poco corrosivo, suficientemente detergente y sobre todo compatible con el producto desinfectante escogido de una parte y el lavado sistemático de los fibroscopios con el fin de descontaminarlos, de otra parte. La extensión más importante de las recomendaciones de desinfección « acelerada » de 4 mn debe permitir realizar cuidadosamente la etapa de lavado sin aumentar el tiempo global de la descontaminación de los endoscopios.



ABSTRACT

We report the results of a national postal survey carried out from January to March 1990, among 1000 gastroenterology endoscopists working in public and private sectors, concerning exclusively the methods of decontaminating digestive fibroscopes between examination (washing, disinfection and rinsing) and the practical difficulties encountered by operators during this decontamination. Only 19% of endoscopists replied to the survey. It transpires from this study that certain aspects of the decontamination of fibroscopes between patients, with the aim of reducing both allergy risks and the problem of obstructing the operating channel of endoscopes deserve a wider exposure : the use of a minimally corrosive washing product, sufficiently detergent and, above all, compatible with the disinfectant chosen on the one hand. The systematic rinsing of fibroscope after decontamination on the other hand. A more widespread use of the 4 mn rapid disinfection recommendations should allow a careful final rinsing stage without increasing the total time taken for decontamination of the endoscopes.



AUTEUR(S)
S. BONVOISIN, R. GIRARD, L. DESCOS, J. FABRY, M. ALISKALI, F. HEDELIUS

MOTS-CLÉS
descontaminación, encuesta postal nacional, fibroscopios digestivos

KEYWORDS
décontamination, digestive tract fibroscopes, national postal enquiry

LANGUE DE L'ARTICLE
Français

 PRIX
• Abonné (hors accès direct) : 34.95 €
• Non abonné : 34.95 €
|
|
--> Tous les articles sont dans un format PDF protégé par tatouage 
   
ACCÉDER A L'ARTICLE COMPLET  (345 Ko)



Mot de passe oublié ?

ABONNEZ-VOUS !

CONTACTS
Comité de
rédaction
Conditions
générales de vente

 English version >> 
Lavoisier