ACCUEIL

Consignes aux
auteurs et coordonnateurs
Nos règles d'éthique
Autres revues >>

ACTA Endoscopica

0240-642X
Revue officielle de la Société Française d'Endoscopie Digestive
Vous êtes sur le site des articles parus entre 1971 et 2014 :
» Accédez aux articles parus depuis 2015 «
 

 ARTICLE VOL 22/3 - 1992  - pp.369-375  - doi:10.1007/BF02965169
TITRE
L’Utilizzazione del laser A Nd: YAG a doppia lunghezza d’onda (1.064 e 1.320 nm) nel trattamento endoscopico delle angiodisplasie del tubo digerente

TITLE
Double wavelength (1 064 nm and 1 320 nm) Nd :YAG laser in the endoscopic treatment of angiodysplasias of the digestive tract

RÉSUMÉ

Il lavoro rappresenta probabilmente il primo studio sulla utizzazione in endoscopia digestiva di un laser a Nd: YAG a doppia lunghezza d’onda (1.064 e 1.320 nm). Le due lunghezza d’onda sono emesse dallo stesso strumento in successione a ritmo rapido. Il laser a lunghezza d’onda 1.064 nm. è quello correntemente utilizzato per l’emostasi e per la ricanalizzazione delle stenosi. Il laser a lunghezza d’onda 1.320 ha una profondità di penetrazione di 0.5 mm. (4 mm per quello a 1.064) e determina una minore dispersione di calore dovuta al sanguinamento ed una diffusione più uniforme nei tessuti circostanti. Nei visceri con parete sottile permette di operare con maggiore sicurezza e ridotto rischio di perforazione. Lo studio presente riporta i dati preliminari paragonando i risultati ottenuti da una parte routinariamente con il laser a 1.064 nm e dall’altra con il laser a doppia lunghezza d’onda utilizzato con maggiore efficacia nel trattamento di certe lesioni difficili quali 1e angiodisplasie.



ABSTRACT

The present report evaluates the utilisation in digestive endoscopy of double wavelength (1 064 and 1 320 nm) Nd :YAG laser. The two different wavelengths are emitted in rapid succession by the same device. 1 064 nm laser is the one most frequently used in hemostasis and in the recanalization of stenoses. 1 320 nm laser has a penetration of 0.5 mm (compared to 4 mm for 1 064 nm laser), and results in less dispersion of heat, as well as a more even diffusion in adjacent tissues. In conditions in which the gut wall is thin, it makes it possible to operate with a higher degree of safety and a reduced risk of perforation. This study presents some preliminary data comparing the results of successive utilisation, on the one hand with 1 064 nm laser (28 referrals), and, on the other hand, with double wavelength laser (16 referrals), to treat angiodysplasias.



AUTEUR(S)
N. D’IMPERIO, D. BARONCINI, A. PIEMONTESE, A. ALBERANI, F. LONGHI, M. GUERINI

MOTS-CLÉS
angiodisplasia, laser a Nd: YAG a lunghezza d’onda 1.064 e 1.320 nm.

KEYWORDS
angiodysplasias, Nd :YAG laser, 1 064 and 1 320 wavelengths.

LANGUE DE L'ARTICLE
Français

 PRIX
• Abonné (hors accès direct) : 34.95 €
• Non abonné : 34.95 €
|
|
--> Tous les articles sont dans un format PDF protégé par tatouage 
   
ACCÉDER A L'ARTICLE COMPLET  (624 Ko)



Mot de passe oublié ?

ABONNEZ-VOUS !

CONTACTS
Comité de
rédaction
Conditions
générales de vente

 English version >> 
Lavoisier